Table 2.8       Proposed Action and Limit Levels for Water Quality

Parameter (unit)

Action

Limit

Dissolved Oxygen (mg/L)

(surface, middle, bottom)

Surface and middle

5%-ile of baseline data

 

Bottom

5%-ile of baseline data

Surface and middle

4 mg/L except 5mg/L for FCZ

Bottom

2 mg/L

SS (mg/L)

(depth average)

95%-ile of baseline data

99%-ile of baseline data

Turbidity (NTU)

(depth average)

95%-ile of baseline data

99%-ile of baseline data

Notes:

1.       “Depth-average” is calculated by taking the arithmetic means of reading of all three depths.

2.       For DO, non-compliance of the water quality limit occurs when monitoring result is lower than the limit.

3.       For SS and turbidity, non-compliance of the water quality limits occur when monitoring result is higher than the limits.