Lamma Power Station Extension - Air Quality Monitoring Data |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24-hr TSP (ug/m3) |
|
|
|
|
1-hr TSP
(ug/m3) |
|
|
|
Date |
Reservoir |
East Gate |
Ash Lagoon |
Tai Yuen Village |
|
Date |
Time |
Reservoir |
East Gate |
Ash Lagoon |
(AM1) |
(AM2) |
(AM3) |
(AM4) |
|
(AM1) |
(AM2) |
(AM3) |
06/02/2005 |
23 |
41 |
32 |
47 |
|
06/02/2005 |
15:00-15:59 |
43 |
34 |
35 |
12/02/2005 |
47 |
44 |
46 |
54 |
|
16:00-16:59 |
36 |
21 |
43 |
18/02/2005 |
80 |
80 |
59 |
56 |
|
17:00-17:59 |
24 |
24 |
16 |
24/02/2005 |
66 |
50 |
81 |
72 |
|
12/02/2005 |
15:00-15:59 |
48 |
41 |
51 |
|
|
|
|
|
|
16:00-16:59 |
52 |
46 |
32 |
|
|
|
|
|
|
17:00-17:59 |
51 |
44 |
24 |
|
|
|
|
|
|
18/02/2005(1) |
15:00-15:59 |
36 |
43 |
87 (19/2) |
|
|
|
|
|
|
16:00-16:59 |
48 |
55 |
51 (19/2) |
|
|
|
|
|
|
17:00-17:59 |
51 |
52 |
52 (19/2) |
|
|
|
|
|
|
24/02/2005 |
15:00-15:59 |
66 |
85 |
75 |
|
|
|
|
|
|
16:00-16:59 |
61 |
61 |
52 |
|
|
|
|
|
|
17:00-17:59 |
55 |
47 |
65 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1) TEOM 1-hr
TSP sampler at AM3 (Ash Lagoon) was found defective on 18/02/2005. A make-up 1hr TSP sampling for AM3 |
|
was carried out on
19/02/2005. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|