Lamma Power Station Extension - Air Quality Monitoring Data
24-hr TSP  (ug/m3) 1-hr TSP  (ug/m3)
Date Reservoir East Gate Ash Lagoon Tai Yuen Village Date Time Reservoir East Gate Ash Lagoon
(AM1) (AM2) (AM3) (AM4) (AM1) (AM2) (AM3)
04/10/2005 56 42 39 47 04/10/2005 15:00-15:59 57 43 33
10/10/2005 74 66 70 85 16:00-16:59 34 35 39
16/10/2005 154 * 147 151 17:00-17:59 50 48 47
18/10/2005 - 111 - - 10/10/2005 15:00-15:59 84 82 75
22/10/2005 118 116 113 # 16:00-16:59 89 88 86
25/10/2005 - - - 58 17:00-17:59 80 80 77
28/10/2005 46 49 41 63 16/10/2005 15:00-15:59 161 155 138
16:00-16:59 140 140 127
17:00-17:59 135 131 128
22/10/2005 15:00-15:59 123 130 113
16:00-16:59 119 122 109
17:00-17:59 123 115 112
28/10/2005 15:00-15:59 40 44 41
16:00-16:59 43 41 46
17:00-17:59 44 48 47
* - 24-hr TSP sampler at AM2 (East Gate) was found defective on 17/10/2005, during the collection of filter sample.
     Defect was rectified on the same day.  A 24-hr TSP make-up sampling was conducted on 18/10/2005.
# - 24-hr TSP sampler at AM4 (Tai Yuen Village) was found defective on 24/10/2005, during the collection of filter sample.
     Defect was rectified on the same day.  A 24-hr TSP make-up sampling was conducted on 25/10/2005.