APPENDIX D  AIR QUALITY MONITORING RESULTS

 

Site: Lamma Power Station Extension

 

Month: April 2005

 

24 hour TSP Measurement:-

Date

TSP concentration (mg/m3)

Weather Information

(From Hong Kong Observatory)

Reservoir

 

(AM1)

East

Gate

(AM2)

Ash Lagoon

 

(AM3)

Tai Yuen Village

(AM4)

Mean Wind Speed

(km/hr)

Prevailing Wind Dir.

(°)

Mean R.H.

 

(%)

01/04/2005

31

30

35

46

27.7

070

91

07/04/2005

51

47

50

67

8.3

060

86

13/04/2005

44

43

41

46

25.8

020

91

19/04/2005

60

59

57

79

10.3

080

79

25/04/2005

36

37

36

72

12.4

090

91

 

1 hour TSP Measurement:-

Date

Time

TSP concentration (mg/m3)

Reservoir

(AM1)

East Gate

(AM2)

Ash Lagoon

(AM3)

01/04/2005

15:00-15:59

33

34

32

16:00-16:59

33

36

36

17:00-17:59

32

33

32

07/04/2005

15:00-15:59

48

52

46

16:00-16:59

54

43

50

17:00-17:59

55

54

53

13/04/2005

15:00-15:59

70

68

70

16:00-16:59

81

59

62

17:00-17:59

73

66

69

19/04/2005

15:00-15:59

76

77

61

16:00-16:59

67

95

59

17:00-17:59

71

71

63

25/04/2005

15:00-15:59

33

35

34

16:00-16:59

33

34

30

17:00-17:59

37

35

36

 

Remark:

(1)            The monitoring stations, Reservoir, East Gate & Ash Lagoon are located within Lamma Power Station.

 

 

                                                                        1-hr TSP                24-hr TSP

                                                                          (mg/m3)                   (mg/m3)

Action Level                                                      340                          190

Limit Level                                                          500                          260

 

 

Calibration:            Calibration details are shown in appendix F.

 

 

Equipment used:

Location

1-hr TSP

24-hr TSP

Reservoir and East Gate

TEOM 1400a

High Volume Air Sampler

Ash Lagoon

Partisol Model 2000 Sampler

Tai Yuen Village

-

MINIVOL Portable Sampler