APPENDIX D  AIR QUALITY MONITORING RESULTS

 

Site: Lamma Power Station Extension

 

Month: November 2017

 

24 hour TSP Measurement:-

Date

TSP concentration (mg/m3)

Weather Information

(From Hong Kong Observatory)

Reservoir

 

(AM1)

East

Gate

(AM2)

Ash Lagoon

 

(AM3)

Tai Yuen Village

(AM4)

Mean Wind Speed

(km/hr)

Prevailing Wind Dir.

(°)

Mean R.H.

 

(%)

6/11/2017

63

69

76

79

28.3

60

68

12/11/2017

35

41 (14/11)*

 

40

54

44.1

70

87

18/11/2017

53

41

33

63

20.2

360

83

24/11/2017

73

83

68

22

28.5

360

65

30/11/2017

38

41

22

71

35

70

90

 

Note:

* -    TSP monitoring at AM2 (East Gate) was suspended on 12/11/2017 due to the defective blower of the High Volume Air Sampler. Make-up 24-hr TSP sampling at AM2 was conducted on 14/11/2017.

 

1 hour TSP Measurement:-

Date

Time

TSP concentration (mg/m3)

Reservoir

(AM1)

East Gate

(AM2)

Ash Lagoon

(AM3)

06/11/2017

15:00 - 15:59

42

52

59

16:00 - 16:59

33

82

62

17:00 - 17:59

34

133

76

12/11/2017

15:00 - 15:59

17

17

14

16:00 - 16:59

6

7

12

17:00 - 17:59

17

15

15

18/11/2017

15:00 - 15:59

11

20 (20/11)*

24

16:00 - 16:59

28

18 (20/11)*

42

17:00 - 17:59

39

30 (20/11)*

50

24/11/2017

15:00 - 15:59

44

41

55

16:00 - 16:59

44

47

50

17:00 - 17:59

33

37

48

30/11/2017

15:00 - 15:59

21

24

37

16:00 - 16:59

36

33

44

17:00 - 17:59

35

37

38

 

Note:

* -    TSP monitoring at AM2 (East Gate) was suspended on 18/11/2017 due to the breakdown of the TEOM TSP sampler. Make-up 1-hr TSP sampling at AM2 was conducted on 20/11/2017.

 

                                                                               

                                                                 1-hr TSP                      24-hr TSP

                                                                         (mg/m3)                   (mg/m3)

Action Level                                                      340                         190

Limit Level                                                        500                         260

 

Calibration:          Calibration details are shown in appendix F.

 

Equipment used:

 

Location

1-hr TSP

24-hr TSP

Reservoir and East Gate

TEOM

High Volume Air Sampler

Ash Lagoon

TEOM

TEOM

Tai Yuen Village

-

MINIVOL Portable Sampler