Appendix B    Action
and Limit Levels for Air Quality and Noise Monitoring
Table B.1   Action
and Limit Levels for 1-hour and 24-hour TSP
| 
   Action Level, mg/m3  | 
  
   Limit Level, mg/m3  | 
 |
| 
   1-hour TSP*  | 
  
   340  | 
  
   500  | 
 
| 
   24-hour TSP  | 
  
   190  | 
  
   260  | 
 
T 
No Action/Limit Level for 1-hour TSP is applied
to AM4 where no real time dust monitor is installed.
B.2. Noise
Table B.2   AL
Levels for
Construction Noise (Other than Percussive Piling)
| 
   Parameters  | 
  
   Action  | 
  
   Limit  | 
 
| 
   Noise Levels at the NSR's at Long Tsai Tsuen/Hung Shing Ye and school within the
  village of Tai Wan San Tsuen predicted by the noise alarm monitoring system  | 
  
   When one or more documented complaints are received  | 
  
   a.   75 dB(A) in LAeq,30 min (07:00-19:00 hrs on
  normal weekdays)  (Note 1) b.   subject to statutory control under
  the Noise Control Ordinance (07:00-23:00 hrs
  on holidays and 19:00-23:00
  hrs on all other days).  Set to 60 dB(A) in LAeq,5 min c.   subject to statutory control
  under the Noise Control Ordinance (23:00-07:00
  hrs of next day).  Set to 45 dB(A) in LAeq,5 min  | 
 
| 
   Manual noise monitoring at the nearest Pak Kok Tsui
  residences to cable landing points N4 and N5  | 
 ||
| 
   Note: 1.                 
  For educational
  institution, the limit level shall be 70 dB(A), reduced to 65 dB(A) during
  examination periods.  | 
 ||