APPENDIX D  AIR QUALITY MONITORING RESULTS

 

Site: Lamma Power Station Extension

 

Month: April 2025

24 hour TSP Measurement:-

Date

TSP concentration (mg/m3)

Weather Information

(From Hong Kong Observatory)

Reservoir

 

(AM1)

East

Gate

(AM2)

Ash Lagoon

 

(AM3)

Tai Yuen Village

(AM4)

Mean Wind Speed

(km/hr)

Prevailing Wind Dir.

(°)

Mean R.H.

 

(%)

3/4/2025

45

53

47

7

12.8

50

57

9/4/2025

46

42

35

14

4.0

210

77

15/4/2025

249^

256^

205^

163

12.4

40

48

21/4/2025

36

22

18

25

14.0

190

79

27/4/2025

26

23

22

31

18.4

50

92

 

^ -  Action level exceedances of 24-hour TSP were recorded at AM1 to AM3 on 15 April 2025.  According to the information from EPD, the high dust episode was due to the influence of a dusty air stream associated with the northeast monsoon and all EPD monitoring stations also recorded daily AQO exceedance for RSP.  As such, we are of the view that the 24-hour action level exceedances are non-project related.

 

1 hour TSP Measurement:-

Date

Time

TSP concentration (mg/m3)

Reservoir

(AM1)

East Gate

(AM2)

Ash Lagoon

(AM3)

3/4/2025

15:00 - 15:59

49

140

43

16:00 - 16:59

48

147

41

17:00 - 17:59

44

57

37

9/4/2025

15:00 - 15:59

28

29

27

16:00 - 16:59

24

32

26

17:00 - 17:59

26

33

25

15/4/2025

15:00 - 15:59

226

228

177

16:00 - 16:59

220

231

195

17:00 - 17:59

266

243

219

21/4/2025

15:00 - 15:59

27

20

17

16:00 - 16:59

87

21

17

17:00 - 17:59

124

20

15

27/4/2025

15:00 - 15:59

23

22

21

16:00 - 16:59

21

21

21

17:00 - 17:59

22

21

22

                                                         

                                                                         1-hr TSP              24-hr TSP

                                                                         (mg/m3)                   (mg/m3)

Action Level                                                      340                         190

Limit Level                                                        500                         260
Calibration:          Calibration details are shown in appendix F.

 

Equipment used:

Location

1-hr TSP

24-hr TSP

Reservoir, East Gate and Ash Lagoon

TEOM

TEOM

Tai Yuen Village

-

MINIVOL Portable Sampler